48V DC systems are gaining traction for hazardous area LED lighting in tunnelling because they sit below the 50V threshold that triggers the most stringent electrical safety requirements, while still delivering enough power to run high-output LED fittings across long cable runs. They reduce shock risk, simplify compliance, and hold up better in the wet, dusty conditions found underground.
Specifying hazardous area LED lighting for a tunnelling project involves more than picking fittings rated for the right zone. The supply voltage you choose affects safety compliance, cable sizing, installation cost, and how well the system holds up over the life of the project.
For years, 110V AC was the default for temporary underground lighting on construction sites. More recently, 48V DC has been moving into that space, and the reasons go beyond fashion. There are real engineering and safety arguments behind the shift.
This article explains what is driving the change, where 48V makes sense, and what you need to think about before committing to it on your next tunnelling job.
What Is a 48V DC System and Why Does the Voltage Matter?
A 48V DC system supplies direct current at 48 volts to lighting fittings via a centralised power supply unit. It sits just below the 50V AC / 120V DC threshold recognised in AS/NZS 3000 and IEC standards as the boundary for Extra Low Voltage (ELV). Below that threshold, the risk of lethal electric shock is significantly reduced.
That 50V boundary is not arbitrary. Research into electrocution thresholds informed the international standards, and 48V DC falls consistently below the level at which cardiac fibrillation becomes likely in most exposure scenarios.
For tunnelling environments, where workers regularly handle cables, fittings, and connectors in wet conditions, that margin matters. A fault on a 230V or even 110V system in standing water is a very different situation from a fault on a 48V system.
Why Tunnelling Creates Unique Lighting Challenges
Tunnelling sites are not like a factory floor or even a surface mining pit. The conditions change constantly. Water ingress, dust from boring and blasting, restricted access for maintenance, and the fact that workers are in an enclosed space with no quick exit all shape the way you need to think about electrical systems.
The Ingress Problem
High-pressure water jets used for tunnel face support and cleanup, groundwater seeping through the lining, and condensation from temperature differentials all create a persistently wet environment. Electrical connectors that would last years on a dry site can fail in months underground.
Lower voltage systems are more forgiving of connector degradation. A compromised connection on a 48V system may cause a fitting to fail or flicker. On a 230V system, the same connection can arc, generate heat, and in a methane or dust-laden atmosphere, create an ignition risk.
Long Cable Runs and Voltage Drop
Tunnelling projects can run for hundreds of metres, and temporary lighting has to extend as the face advances. With AC systems, voltage drop over long runs is managed by running at higher voltages. With 48V DC, the approach is different: you space out the power supply units and run shorter distribution legs from each one.
This actually suits tunnelling well. Instead of one large transformer at the portal, you locate smaller 48V power supply units at regular intervals and advance them as the tunnel progresses. Each unit is lighter and easier to handle than a comparable AC transformer.
The Specific Reasons 48V Is Gaining Ground in Tunnelling
1. Compliance Is Simpler Below 50V
In Australia, electrical work on systems operating above 50V AC or 120V DC falls under licensed electrician requirements for installation, testing, and maintenance. Work on ELV systems carries fewer restrictions, which means more of your site crew can handle day-to-day tasks like moving fittings, extending cable runs, and replacing lamps without waiting for a licensed electrician.
On a fast-moving tunnelling project where the lighting layout changes weekly, that operational flexibility is worth a great deal.
2. Reduced Arc Flash and Ignition Risk
In zones classified as hazardous due to the presence of combustible dust or gases, the energy available at a fault point matters as much as the voltage itself. Lower voltage DC systems carry less fault energy, which reduces the risk that a cable fault or connector failure will produce an arc capable of igniting the surrounding atmosphere.
This is one reason why hazardous area LED lighting solutions for underground applications are increasingly being designed around 48V DC supply rather than higher AC voltages.
3. LED Technology Is Well Suited to DC Supply
LED drivers convert AC supply to DC internally before feeding the LED array. By running the distribution system in DC at 48V, you eliminate that conversion step at the fitting level. This improves efficiency slightly, reduces heat generation in the driver, and often extends the working life of the fitting.
Purpose-built LED fittings for 48V DC supply are now available from manufacturers who understand the underground construction and mining market, and the product range has expanded considerably over the last five years.
4. Better Compatibility with Renewable and Battery-Backed Power
Tunnelling projects in remote areas, or those trying to reduce diesel generator reliance, are increasingly looking at battery energy storage systems and solar or hybrid generation. Most of these systems operate natively at 48V DC, which means a 48V lighting distribution network connects directly without an additional inverter stage.
That simplification reduces points of failure and makes it easier to maintain power to lighting during generator switchover events.
What to Look for When Specifying 48V LED Fittings for Tunnelling
Not every LED fitting labelled as suitable for underground use is actually engineered for the conditions you will encounter in an active tunnelling environment. Here is what to check.
Ingress Protection rating: Look for IP66 minimum. IP67 or IP68 is better for areas subject to high-pressure wash-down or temporary flooding.
Impact resistance: IK08 or higher. Fittings will get hit by materials, vehicles, and equipment.
Zone certification: Confirm the fitting is certified for the specific zone classification of your tunnelling environment. Zone 1 and Zone 2 have different requirements, and not all fittings marketed for hazardous areas actually carry the right certification for underground construction.
48V DC native supply: Some fittings accept a wide input range and can run on 48V. Others are purpose-designed for it. Purpose-designed units generally perform better and are easier to maintain in the field.
Sourcing LED lighting for hazardous areas from a supplier who actually understands tunnelling conditions makes a real difference. MineGlow designs and supplies lighting specifically for mining and underground construction, with products tested to the standards required for Australian hazardous zone applications.
When in doubt, ask the supplier for the full certification documentation, not just the compliance label on the product. Certified hazardous area lighting should come with paperwork that shows the testing authority, the standard tested to, and the specific protection concepts applied.
Installation Considerations for 48V Systems in Tunnels
1. Power Supply Unit Placement
Space your PSUs to keep cable runs short enough to avoid significant voltage drop. As a starting point, plan for a maximum run of around 50 metres from PSU to the furthest fitting on that circuit, depending on the cable cross-section and total load. Your supplier or a qualified electrical designer should provide a voltage drop calculation for your specific layout.
2.Cable and Connector Selection
Use connectors rated for the environment. Push-in or screw-lock connectors with IP67 or higher rating hold up better underground than standard plugs. Keep spare connectors on site because they get damaged and need replacing regularly on a working tunnel.
Cable management also matters more than it does on surface sites. Cable trays and cable protection prevent damage from vehicles and falling material, which is one of the more common causes of lighting failures underground.
3.Earthing and Fault Protection
Even on a 48V ELV system, earthing and fault protection should not be ignored. Residual current devices appropriate for DC systems should be used to protect against earth faults, and the earthing arrangement should be designed as part of the overall site electrical installation.
On a system feeding certified hazardous zone fittings, the integrity of the installation affects the protection level the fittings can actually provide. A correctly certified fitting in a poorly installed system does not deliver the level of safety the certification implies.
Where 48V Has Limitations
48V DC is not the right answer for every scenario in tunnelling. Large projects with very long tunnels and high lighting loads may find that the number of PSUs required becomes impractical compared to a higher-voltage AC distribution system with step-down transformers at intervals.
There are also situations where the existing site power infrastructure is entirely built around 110V or 230V AC, and adding a separate 48V DC distribution system creates complexity rather than reducing it. In those cases, a hybrid approach, using 48V only in the most sensitive hazardous zones and AC elsewhere, may be more practical.
Work through the design with a qualified electrical engineer who knows underground construction. The voltage choice should follow the requirements of the project, not the other way around.
Final Thought :
48V DC systems have real advantages in tunnelling: they sit below the ELV threshold, reduce ignition risk in hazardous zones, work well with LED technology, and suit the incremental layout changes that come with an advancing tunnel face. Those advantages are why more engineers and safety officers are specifying them as their default for underground lighting.
Getting the most out of a 48V system still depends on specifying the right fittings for the zone classification, installing them correctly, and maintaining them properly. That is where working with a supplier who knows the underground environment pays off.
MineGlow is worth a look if you are at the specification stage. Their range is built for mining and underground construction applications, certified to Australian standards, and backed by people who understand what those environments actually demand from a lighting system.
Frequently Asked Questions
1.Why is 48V becoming the preferred voltage for underground LED lighting in tunnels?
48V DC sits just below the 50V Extra Low Voltage threshold, which significantly reduces the risk of electric shock in wet underground conditions. It also reduces arc fault energy in hazardous zones, works efficiently with LED drivers, and is easier to advance as the tunnel face progresses. These practical advantages have made it an increasingly common choice for tunnelling lighting systems.
2.What certifications should hazardous area LED fittings carry for use in tunnels?
Fittings should carry Ex certification under the IECEx scheme or the Australian AUS Ex scheme, with a certification class matching the zone in which they will be installed. Zone 1 requires a higher level of protection than Zone 2. Check the specific gas group and temperature class on the certification plate and confirm they match your site’s hazardous area classification.
3.Can standard LED strip lights be used in hazardous area tunnelling applications?
No. Standard LED strip lights are not certified for use in explosive atmospheres. Fittings used in classified hazardous zones must carry the appropriate Ex certification. Using uncertified equipment in a hazardous zone is a safety and compliance breach regardless of how the product is marketed.
4.How far can you run cable from a 48V power supply unit to LED fittings underground?
As a general guide, keep runs to around 50 metres or less depending on the cable cross-section and the total load on the circuit. Longer runs cause voltage drop that can affect fitting performance and reliability. Your electrical designer should calculate the maximum run length based on your specific cable specification and load.
5.What IP rating do LED fittings need for active tunnelling environments?
At minimum, IP66 for areas subject to dust and water spray. For areas subject to high-pressure washdown or temporary submersion, IP67 or IP68 is more appropriate. Check the fitting’s IK rating as well; IK08 or higher gives better protection against the physical impacts that are common in active construction tunnels.